Bellman Visit Typical House Wireless Alerting Bundle
Code: 44BEK07B
Quantity Pricing
VAT Relief is available if you make a declaration in the Shopping Basket
-
VAT
Choose quantity
Order now for dispatch on Mon 2nd Feb.
Description
The Bellman Visit 'typical house' wireless alerting bundle contains everything you need to get started with smart alerts within your home.
An ideal solution for anyone who is deaf or hard of hearing this kit includes a landline telephone transmitter, existing doorbell/intercom transmitter and 2 x smoke alarm transmitters (optical with heat sensor) for alerts in the event of a fire. The transmitters send a signal to the the Visit Pager Kit (44BEK01) which includes a charger as well as a bed shaker so you can receive alerts at night.
The pager alerts you with discreet vibrations and can run on a single AAA alkaline battery for up to three weeks and because it is robust and lightweight, it can be neatly attached to your belt or be tucked away in your pocket. This means you can receive a doorbell, landline telephone or smoke alarm alert wherever you are within the home, whether you're in the garden, the kitchen, the lounge etc.
The Bellman Visit range is ideal for anyone who is deaf or hard of hearing as it provides alerts via lights, sounds and vibrations, so you can immediately be alerted whenever something happens that needs your attention in and around your home.
Pager Features:
- Pager provides discreet vibrations and can be placed in the charging cradle for use at night time alongside the vibrating bed shaker
- Powerful portable receiver sound - adjustable up to 93dB
- The pager is portable and lightweight - wear it on your belt or in your pocket
- Simple to set up - system works straight out of the box
- 868 MHz
- RJ11 input for landline telephone
- 2.5mm external trigger input for mobile phone sensor
- 3.5mm external trigger input for other accessories
- Long lasting power - up to 10 years battery life
- Secure radio link with up to 250m operating range
- Flexible use - detects the doorbell & intercom
- Built in dual microphone technology for reliable detection
- Programmable - teach it to recognise any sound - this means you do not have to replace your current doorbell
- Long lasting power - up to 10 years battery life
- Secure radio link with up to 250m operating range
- Battery supervision - Signals the Visit receiver when the batteries run low
- Toast mode - suitable for use in areas with cooking fumes
- Test button - all smoke alarm systems should be tested regularly
- Broadcast mode - relays alarms to all Visit units within range
- Reliable radio link - covers your entire home with up to 200m operating range
- Complies with the following smoke alarm standards: EN14604: 2005 standard + AC:2008
Inside the box:
BE1470 Visit Pager, BE1260 Pager Charger with pre-mounted
backup batteries, UK Power supply, 1 x AAA NiHM rechargeable
battery, supporting legs and screws, BE1270 Vibrating Bed Shaker,
Belt Clip, Safety Cord, Extra Front Label, User Manuals.
BE1411 Visit door transmitter , 2 x AA alkaline batteries, velcro for wall mounting, alcohol wipe, screw and plug, user manual.
BE1431 Visit telephone transmitter , 2 x AA alkaline batteries, velcro for wall mounting, telephone cord and adaptor, screw and wall plug.
2 x BE1481 Visit smoke alarm, 2 x 1.5V AA batteries, screws and plugs, user manual.
Details
Visit indicators:
- Orange LED, pacifier/dummy symbol: The baby monitor is activated
- Green LED, door symbol: The door transmitter is activated
- Yellow LED, telephone symbol: The telephone transmitter is activated
- Red LED, fire symbol: The smoke alarm is activated
Frequency and coverage:
- Radio frequency: 868.3 MHz
- Coverage: 50 – 250 metres depending on the radio frequency and building’s characteristics
Pager Features:
- Clear signal identification: Coloured LEDs and individual sound signatures
- Discreet alerts: Produces silent and non-intrusive vibrations
- Lightweight and portable: Weighs only 70g
- BE1260 charger accessory: Equipped with two bed shaker sockets (bed shaker included)
Pager Power and battery:
- Mains power - powered via the BE1260 Charger (included)
- Battery Power 1 x AAA alkaline (or rechargeable) battery
- Power consumption: Active: 220 mA, idle position: 1 mA
- Operating time: 2-3 weeks with an alkaline battery or 1 week with NiMH battery (fully charged)
Door Transmitter features:
Inputs/outputs:
- External microphone input
- External trigger input
How is it activated?:
- The test buttons and the internal microphone
- The built-in electromagnetic detector
- The external microphone accessory BE9199/BE9200 (sold separately)
- The existing doorbell connected to the external trigger
Frequency and coverage:
- Radio frequency: 868.3 MHz
- Coverage: 50 – 250metres depending on the radio frequency and building’s characteristics
Power and battery:
- Supply - Battery power 2 x AA lithium or alkaline
- Power consumption: Active: <70 mA, idle position: 15 mA
- Operating time: 5 year with alkaline batteries, 10 years with lithium batteries
Landline Telephone Transmitter features:
Inputs/outputs:
- RJ11 input to analogue telephone network
- External microphone input
- External trigger input
How is it activated?:
- The test buttons and the internal microphone
- A smartphone/tablet via the mobile phone sensor (sold separately)
- Contact mat BE9024 or magnetic switch BE9023 accessories (sold separately)
- The existing doorbell connected to the external trigger
Frequency and coverage:
- Radio frequency: 868.3 MHz
- Coverage: 50 – 250metres depending on the radio frequency and building’s characteristics
Power and battery:
- Supply - Battery power 2 x AA lithium or alkaline
- Power consumption: Active: <70 mA, idle position: 15 mA
- Operating time: 5 year with alkaline AA batteries, 10 years
with lithium AA batteries
Smoke Alarm Features:
- Sensor type - optical smoke detection and thermal detection
-
- BE1481 complies with the following smoke alarm standard: EN14604: 2005 + AC:2008
- Audible alarm > 85dB (A) at 3m
- Activation:
- Via test and silence button
- Via the smoke detector
- Via the temperature sensor, if the temperature exceeds approx 57 degrees celcius
Frequency and coverage:
- Radio frequency: 868.3 MHz
- Coverage: up to 200m clean line of sight, depending on the radio frequency and building’s characteristics
Power and battery:
- Supply - 2 x 1.5V AA batteries
- Power consumption: Active:< 75mA, idle position: <15 mA
- Operating time: Lithium Battery - 5 years
Help Centre
Click here to view pdf user guide for the Bellman Visit Pager Charger
Click here to view pdf data sheet for the Bellman Visit Pager Charger
Click here to view pdf user guide for the Visit Pager Receiver
Click here to view pdf data sheet for the Visit Pager Receiver
Click here to view PDF user guide for the Visit Vibrating Bed Shaker
Click here to view PDF data sheet for the Visit Vibrating Bed Shaker
Click here to view pdf user guide
for the Visit Doorbell Transmitter
Click here to view pdf data sheet for the Visit Doorbell Transmitter
Click here to view pdf user guide for the Visit Telephone Transmitter
Click here to view pdf data sheet for the Visit Telephone Transmitter
Click here to view pdf installers
guide for the Visit smoke alarm transmitter
Click here to view pdf data sheet
for the Visit smoke alarm transmitter
Click here to view pdf user
manual for the Visit smoke alarm transmitter